1 Alternator 2 Batteries, 70 amps, SENSE.. Input Voltage: 6-50VDC, Peak Output: 70 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 702 Except Different Packaging,
ISO 70A 1INP 2BAT1 Alternator 2 Batteries, 70 amps, Input Voltage: 6-50VDC, Peak Output: 70 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 702 Except Different Packaging, Application: Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
Maximum
Alternator
Rating
Recommended Wire Size / Circuit Breaker
Up to 15ft
15ft to 20 ft
20ft to 25ft
25ft to 30ft
70 Amps
#8 ga. / 50 amp
#6 ga. / 50 amp
95 Amps
#4 ga. / 50 amp
130 Amps
#6 ga. / 80 amp
#4 ga. / 80 amp
#2 ga. / 80 amp
#1 ga. / 80 amp
160 Amps
#4 ga. / 120 amp
#2 ga. / 120 amp
#0 ga. / 150 amp
240 Amps
#000 ga. / 150 amp
#0000 ga. / 150 amp
ISO 70A 1INP 3BAT REG SEN
1 Alternator 2 Batteries, 70 amps, 702P
1202R- Battery Isolator, Single Input Dual Battery Isolator
1 Alternator 2 Batteries, 70 amps, Input Voltage: 6-50VDC, Peak Output: 70 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 702 Except Different Packaging,
MINIMUM PURCHASE QUANTITY: 24FOR SMALLER PURCHASE QUANTITIES SEE SP-SP952ISO 95A 1INP 2BA1 Alternator 2 Batteries, 95 amps, Input Voltage: 6-50VDC, Peak Output: 95 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 952D Except Different Packaging, Application: Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
703- Battery Isolator, 1 Alternator 3 Batteries, 70 amps
Input Voltage: 6-50VDC, Peak Output: 95 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal
MINIMUM ORDER QUANTITY: FOR SMALLER ORDER QUANTITIES SEE SP-SP1202ISO 120A 1INP 2BAT
1 Alternator 2 Batteries, 120 amps, Input Voltage: 6-50VDC, Peak Output: 120 amps, Continuous Output: 120 amps, Notes: Single Input, Dual Battery Isolator With (3) 5/16-18 Threaded Terminals, Same As SP #1202D Except In a Box, Includes Mounting Hardware, OVERALL LENGTH: 190.5mm/7.5", Application: Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
9523A Battery Isolator for Delco CS & CS-D Series Alternators
1203 Sure Power Input Voltage: 6-50VDC, Peak Output: 120 amps, Continuous Output: 120 amps, Single Input, Three Battery Isolator
1 Alternator 2 Batteries, 160 amps, Input Voltage: 6-50VDC, Peak Output: 160 amps, Notes: Single Input, Dual Battery Isolator, Includes Mounting Hardware, OVERALL LENGTH:317.5mm/12.5",
1602 POSITIVE1 Alternator 2 Batteries, 160 amps, Input Voltage: 6-50VDC, Peak Output: 160 amps, Notes: Single Input, Dual Battery Isolator, Includes Mounting Hardware, OVERALL LENGTH:317.5mm/12.5",
1203R Sure Power 120amp Single Input, Three Battery Isolator
Input Voltage: 6-50VDC, Peak Output: 120 amps, Continuous Output: 120 amps
Input Voltage: 6-50VDC, Peak Output: 120 amps, Continuous Output: 120 amps,
2703R, Eliminate multi-battery drain when two or more battery banks are in a charging system.
2002 sure power Isolator 200 amps
16023A, 160 Amp, 1 Input, 2 Battery Isolator - DELCO SERIES
2703, Eliminate multi-battery drain when two or more battery banks are in a charging system.
The Schottky diode multi-battery isolator is required for federal KKK-A-1822A specifications because it offers a lower voltage drop than conventional battery isolators .
20023A- ISO-200A-1INP-2BAT-CS,
Battery Isolator 160 amp 1 input 3 Battery
3202 Battery Isolator, 120 amps, 2 in - 2 out
Battery Isolator, 1 Alternator 2 Batteries, 240 amps
1 Alternator 2 Batteries, 240 amps, Input Voltage: 6-50VDC, Peak Output: 240 amps, Notes: 1 Input Terminal and 2 Battery Terminals Are 3/8-16 Thread, OVERALL LENGTH: 317.5mm/12.5"
Battery Isolator Delco Marine CS & CS-D Series Alternators plus any Alternator that Requires Ignition Sense to Activate Regulator
3203- Battery Isolator, 6-50VDC, Peak Output: 120 amps