Submit search
4 pin connector for the trail charger
Sure Power 640042B Connector
sure power fuse kit 1591
sure power fuse kit 1594
sure power fuse kit 1597
sure power fuse kit 1595
MINIMUM PURCHASE QUANTITY: 20FOR SMALLER ORDER QUANTITIES SEE SP-SP1421FLASHER 25A 12V
ACCESSORY SOLENOID
SOLID STATE FLASHER 25A 12V
PACKAGED ISO 25A 1INP 2BA
FLASHER 25A 24V BULB
ISO 70A 1INP 2BAT1 Alternator 2 Batteries, 70 amps, Input Voltage: 6-50VDC, Peak Output: 70 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 702 Except Different Packaging, Application: Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
Maximum
Alternator
Rating
Recommended Wire Size / Circuit Breaker
Up to 15ft
15ft to 20 ft
20ft to 25ft
25ft to 30ft
70 Amps
#8 ga. / 50 amp
#6 ga. / 50 amp
95 Amps
#4 ga. / 50 amp
130 Amps
#6 ga. / 80 amp
#4 ga. / 80 amp
#2 ga. / 80 amp
#1 ga. / 80 amp
160 Amps
#4 ga. / 120 amp
#2 ga. / 120 amp
#0 ga. / 150 amp
240 Amps
#000 ga. / 150 amp
#0000 ga. / 150 amp
ISO 70A 1INP 3BAT REG SEN
1202R- Battery Isolator, Single Input Dual Battery Isolator
1 Alternator 2 Batteries, 70 amps, Input Voltage: 6-50VDC, Peak Output: 70 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 702 Except Different Packaging,
FLASHCUBE 38A 18 BULB
MINIMUM PURCHASE QUANTITY: 24FOR SMALLER PURCHASE QUANTITIES SEE SP-SP952ISO 95A 1INP 2BA1 Alternator 2 Batteries, 95 amps, Input Voltage: 6-50VDC, Peak Output: 95 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 952D Except Different Packaging, Application: Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
1 Alternator 2 Batteries, 70 amps, SENSE.. Input Voltage: 6-50VDC, Peak Output: 70 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal, (2) M6-1.0 Threaded Battery Terminals and Mounting Hardware Same As 702 Except Different Packaging,
1 Alternator 2 Batteries, 70 amps, 702P
FLASHER 3 WIRE wSOUND
703- Battery Isolator, 1 Alternator 3 Batteries, 70 amps
FLASHER 3 WIRE
Input Voltage: 6-50VDC, Peak Output: 95 amps, Notes: Includes (1) M6-1.0 Threaded Input Terminal
MINIMUM ORDER QUANTITY: FOR SMALLER ORDER QUANTITIES SEE SP-SP1202ISO 120A 1INP 2BAT
1 Alternator 2 Batteries, 120 amps, Input Voltage: 6-50VDC, Peak Output: 120 amps, Continuous Output: 120 amps, Notes: Single Input, Dual Battery Isolator With (3) 5/16-18 Threaded Terminals, Same As SP #1202D Except In a Box, Includes Mounting Hardware, OVERALL LENGTH: 190.5mm/7.5", Application: Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
9523A Battery Isolator for Delco CS & CS-D Series Alternators
1314 sure power BAT SEP 12V W AUX START
1315 sure power battery separator 12V W AUX start 100amp
MINIMUM PURCHASE QUANTITY:12FOR SMALLER ORDER QUANTITIES SEE SP-SP1302ISO 130A 1INP 2BATVolts: 6-50VDC Volts 130 Amps Input Terminals: 1 Terminals: 2 Mounting Length: 128.7mm / 5.067in Mounting Width: 108.2mm / 4.260in Mounting Height: 62.5mm / 2.461in Single Input, Dual Battery Isolator, Includes Mounting Hardware, Negative Ground Battery Isolator For OEM Delco (GM) Except CS Series Alternators, All Motorcraft (Ford), All Mopar (Chrysler), Japanese Imports Using External Voltage Regulators or External Sensing, Motorola Load Handler Series and 8EM Remote Sense Series Alts
1203R Sure Power 120amp Single Input, Three Battery Isolator